Explore GE Vernova
Products & Services
Industries
News & Events
About Us
Resources
Thought Leadership
Resource Library
Get access to curated content, tools, and useful resources to help you face all your grid challenges.
Access the library
HV/MV Equipment
Grid Automation
Systems & Software
Services
Overview
Transformers
Gas-Insulated Solutions
Circuit Breakers
Disconnectors (Switches)
Instrument Transformers
Capacitors & Reactors
Voltage Regulators
Bushings, Arresters & Insulators
Digital Monitoring & Control Solutions
SF
6
-free Solutions (g
3
)
Overview
Asset Monitoring
Protection Relays
Automation & Control
Advanced Automation Systems
Substation Solutions
Communications
Automation & Protection Services
Device Management (DvM)
Systems
Overview
HVDC Systems
FACTS
Electrical Balance of Plant
Substation Projects
Microgrids & Renewable Integration
Energy Storage Solutions
Software
Transmission - AEMS & AMMS
Wide Area Management System
Outage Response
Geospatial Asset Management
Overview
Flexible Service Agreements
HV/MV Equipment Services
HVDC & FACTS Services
Automation & Protection Services
Software Services
Consulting Services
Technical Training
Cybersecurity
Asset Lifecycle Management
Generation
Microgrids & Renewable Integration
Water & Wastewater
Transmission
Data Centers
Oil & Gas
Distribution
Industry & Infrastructure
Mining
Digital Energy
Distribution
Distribution Protection
Select a typical application to view the associated one line diagram, functions,
and product order codes.
Directional Overcurrent
Directional Overcurrent - Dual Breaker
Non Directional Overcurrent
Directional Overcurrent
Typical Functions
67
67N
25
79
V, S
Phase directional overcurrent
Neutral directional
overcurrent
Synchrocheck
Reclosing
Voltage and Power metering
Functions
Typical Product Order Code
Typical Functions
760-P5-G5-S5-HI-A20-G-T
F650-M-A-D-1-0-HI
F60-N00-HCH-F8L-H6P-MXX-PXX-UXX-WXX
+ Additional Functions
Included in typical
Directional Overcurrent - Dual Breaker
Typical Functions
67
67N
25
79
V, S
Phase directional overcurrent
Neutral directional
overcurrent
Synchrocheck
Reclosing
Voltage and Power metering
Functions
Typical Product Order Code
Typical Functions
760-P5-G5-S5-HI-A20-G-T
F650-M-A-D-1-0-HI
F60-N00-HCH-F8L-H6P-MXX-PXX-UXX-WXX
Non Directional Overcurrent
Typical Functions
50
51
79
Phase/Ground IOC
Phase/Ground TOC
Reclosing
Functions
Typical Product Order Code
Typical Functions
760-P5-G5-S5-HI-A20-G-T
F35-N00-HCH-F8L-H6P-MXX-PXX-UXX-WXX
350E-P5-G5-H-S-C-1E-H