Digital Energy Protection & Control Meters
Protection & Control Online Store
Protection & Control Support
Protection & Control Press Room
Resources
  Brochures
  Manuals
  Specifications
  Software
 
Related Links
  EPM Metering Device Family
  EPM 2200
  EPM 9450
  EPM 9650
  EPM 7000
  PQM II
  EnerVista PMCS
  EnerVista
  Energy Aggregator
  Multilin Meter Enclosure
 

 

 
EPM 6000 Power Meter
High Accuracy Power
and Energy Measurement


EPM 6000 is the industry's highest performance revenue grade panel meter. Based on the latest technology and an all new platform, EPM 6000 has a superior cost to performance ratio and significantly outperforms other metering products many times its price.

EPM 6000 can easily by mounted in a panel for generator monitoring, substation automation and more. The unique combined ANSI and DIN mounting structure allows easy installation making it perfect for new metering applications as well as retrofit for existing analog meters.

This meter is available in a transducer configuration (EPM 6000T) that comes without a display and has a DIN rail mount. It’s ideal for use in retrofit applications and where budgets are a large consideration.

Key Benefits
  • High accuracy Multifunction Power meter
  • User programmable for different system voltages and current measurements
  • Ultra compact, easy to install, program and use
  • 0.2% Class Revenue Certifiable energy and demand metering
  • Fits both ANSI and DIN cut-out

  • Large 3 line .56" bright LED display for better visibility and longer life
  • User programmable for different system voltages and current measurements
  • Optional Ethernet port for easy integration of meters directly onto Ethernet LANs
Applications
  • Continuous metering of electrical loads such as generator panels, feeders,
    switchgear, etc.
  • Provides remote status when used with EnerVista suite of software
  • Low and Medium voltage applications
  • Replaces multiple analog meters saving space and installation costs
  • Monitoring and Metering
  • True RMS multifunction measurements including Voltage, Current, Power,
    Frequency, Energy, etc.
  • Meets ANSI C12.20 (0.2%) and IEC 687 (0.2%) Accuracy Classes
  • Future field upgradeable for added functionality without removing installed meter
  • Load percentage graphical bar for instant load visualization
  • User Interface
  • RS485 Modbus Protocol up to 57.6K Baud
  • Optional upgrade from serial to Ethernet communications for simplified LAN integration and multi-point connectivity
  • 3 Line .56" Bright Red LED Display
  • Front IRDA Port laptop communication
  •  

    COMMUNICATIONS

    Through a built-in infra-red (IrDA) port , the meter can be programmed through a lap top computer without a physical wire connection to the meter, making programming or data download convenient and safe. Using standard high speed Modbus communications, the meter can also provide data to RTUs, PLCs and other control devices. When used with the EnerVista suite of software, the meter can be remotely monitored.

    The EPM 6000 provides two independent communication ports with advanced features.

    The meter allows voltage inputs measurements up to 416 Volts Line to Neutral and 721 Volts Line to Line. This insures proper meter safety when wiring directly to high voltage systems. The unit will perform to specification on 69 Volt, 120 Volt, 230 Volt, 277 Volt and 347 Volt power systems.

    IrDA port – Uniquely the unit has an optical IrDA port allowing the unit to be set up and programmed using a remote laptop without needing a communication cable. Just point at the meter with an IrDA equipped PC computer and configure it. The second port is factory selectable to be either a RS485 port or an Ethernet port with features as follows:

    • RS485 Port – This port provides RS485 communication using Modbus ASCII or Modbus RTU or DNP 3.0 protocol. Baud rates are from 9600 to 57.6 kbaud
    • Ethernet Port – This port provides connectivity via a 10/100BaseT RJ45 connection. Modbus TCP protocol is supported

    SOFTWARE
    EnerVista Software

    EnerVista Launchpad is a powerful software package that provides users a platform to access all of the setup and support tools needed for configuring and maintaining GE’s Multilin products. Launchpad allows configuration of devices in real-time by communicating using RS232, RS485, Ethernet, or modem connections. Using Launchpad as the single interface to the setup and analysis software makes it simple to enter setpoints, read metered values, monitor status and evaluate power quality. Included in Launchpad is a document archiving and management system that ensures critical documentation is up-to-date and available when needed by automatically checking for and downloading new versions of manuals, applications notes, specifications, and service bulletins.

    Viewpoint Monitoring

    Viewpoint Monitoring is a simple-to-use, full-featured monitoring and data recording software package for small systems. Viewpoint Monitoring provides a complete HMI package that instantly puts critical real-time device data on your PC through pre-configured graphical screens with the following functionality.

    • Plug-&-Play Device Monitoring
    • System Single-Line Monitoring & Control
    • Annunciator Alarm Screens
    • Trending Reports
    • Automatic Event Retrieval
    • Automatic Waveform Retrieval
    EnerVista Integrator

    EnerVista Integrator is a toolkit that allows seamless integration of GE Multilin devices into new or existing automation systems by sending GE device data to HMI, DCS, and SCADA systems. Included in EnerVista Integrator is:

    • OPC/DDE Server
    • GE Multilin Drivers
    • Automatic Event Retrieval
    • Automatic Waveform Retrieval

    USER INTERFACE
    INSTALLATION
    Unique Current Input Connections

    EPM 6000 meter uses a two current input wiring methods.

    • Method One - CT pass through. Directly pass the CT through the meter without any physical termination on the meter. This insures that the meter cannot be a point of failure on the CT circuit. This is preferable to utility users when sharing relay class CTs. No Burden is added to the secondary CT circuit.
    • Method Two - Current “Gills.” The meter additionally provides ultra-rugged termination pass through bars allowing the CT leads to be terminated on the meter. This also eliminates any possible point of failure at the meter. This method is also a preferred technique for ensuring relay class CT integrity does not get compromised. No terminal blocks are required and this stud based design ensures that CTs will not open under a fault condition.
    SPECIFICATIONS
    EPM 6000T Multifunction Power Metering System - Transducer Option

    The EPM 6000 is available in a transducer configuration. This meter version comes without a display and has a DIN rail mount. It’s ideal for use in switchgear retrofit applications where access to the meter face and display is not necessary, and where budgets are a large consideration.

    Features
    • EPM 6000 Power Meter without display, DIN mount
    • Mounts directly in ANSI C39.1 (4” round form) or and IEC 92mm DIN square form
    • Uses minimal panel space with 4.25” panel depth
    • Multifunction Power and Energy Meter
    • 0.2% Watt-hour accuracy
    • Ethernet communications

    Mounting

    MULTILIN METER ENCLOSURE
    Expanding existing switchgear or installing new metering capability can be challenging due to space limitations, downtime and installation and equipment costs. GE's Multilin Meter Enclosure is a pre-wired configured, economical solution for both retrofit expansions and small scale meter installations that allows the expansion of existing switchgear capability without expensive and time-consuming design.

    When ordered as a meter option the enclosure provides a factory pre-wired, installation-ready metering solution that further drives energy cost savings, by enabling the measurement of key energy usage information along multiple metering points for new or existing systems.

    Ordering the enclosure is simple when selected as an option during meter configuration, ensuring correct pre-wired meter-compatible delivery.

    Pre-Wired, Configured and Economical Solution for Retrofit and Small Metering Systems
    Easy and Rapid Installation

    • Factory pre-wired, installation-ready GE metering solution eliminates wiring and associated errors for rapid installation
    • Extend metering capability with new systems and existing switchgear without system installation downtime

    Cost-Effective Retrofit Solution

    • Save up to 200% versus the addition of a new switchgear cabinet
    • Compact footprint makes effective use of existing allocated space
    • Allows new installations or the expansion of existing switchgear capability without expensive, time-consuming designs, eliminating system downtime

    Reliable and Compatible

    • Backed by a two-year warranty
    • Simple meter option ordering ensures compatibility with GE EPM 2000/6010/6000/7000 meters
    • Comprehensive factory testing of both meter and enclosure together
    • NEMA1 tested and UL/CUL certified
    Applications (New and Retrofit installations)

    • Industrial Multi-Tenant Monitoring
    • Commercial/Residential Buildings
    • Healthcare Institutions
    • Government Buildings
    • Manufacturing
    • Educational Campuses

     


    Assembly


     


    Diagram